<p style="text-align: center;">Le laboratoire dispose de 5 spectromètres UV-VIS</p>
<ul style="list-style-type: circle;">
<li><strong>le Cary 1, le Cary 100 et le Cary 300 (Société Varian)</strong></li>
</ul>
<img class="size-medium wp-image-3439 aligncenter" src="https://lasir.cnrs.fr/wp-content/uploads/2019/01/cary300-300x225.jpg" alt="" width="300" height="225" />
<table class="aligncenter" style="width: 32.3759%; border-collapse: collapse;" border="1">
<tbody>
<tr>
<td style="width: 28.6576%; text-align: center;"></td>
<td style="width: 71.0407%; text-align: center;">Cary 1, Cary 100, Cary 300</td>
</tr>
<tr style="height: 50px;">
<td style="width: 28.6576%; height: 36px;">Gamme spectrale</td>
<td style="width: 71.0407%; height: 36px;">190-900 nm</td>
</tr>
<tr style="height: 56px;">
<td style="width: 28.6576%; height: 35px;">Résolution spectrale</td>
<td style="width: 71.0407%; height: 35px;">0.2-4 nm</td>
</tr>
<tr style="height: 36px;">
<td style="width: 28.6576%; height: 36px;">Détecteur</td>
<td style="width: 71.0407%; height: 36px;">Photomultiplicateur</td>
</tr>
<tr>
<td style="width: 28.6576%;">Sources</td>
<td style="width: 71.0407%;"><span style="font-size: 10pt;">Vis : Tungstène-halogène</span>
<span style="font-size: 10pt;">UV : Deutérium</span></td>
</tr>
</tbody>
</table>
<ul style="list-style-type: circle;">
<li><strong>le Cary 5000 et le Cary 6000 (Société Varian)
</strong></li>
</ul>
<img class="size-medium wp-image-3440 aligncenter" src="https://lasir.cnrs.fr/wp-content/uploads/2019/01/cary5000-300x225.jpg" alt="" width="300" height="225" />
<table class="aligncenter" style="height: 254px; width: 73.7157%; border-collapse: collapse;" border="1">
<tbody>
<tr style="height: 28px;">
<td style="width: 3.9304%; height: 28px;"></td>
<td style="width: 6.39214%; background-color: #e3e1e1; height: 28px;"><span style="font-size: 10pt;">Cary 5000</span></td>
<td style="width: 7.05377%; height: 28px;"><span style="font-size: 10pt;">Cary 6000</span></td>
</tr>
<tr style="height: 28px;">
<td style="width: 3.9304%; height: 28px;"><span style="font-size: 10pt;">Gamme Spectrale</span></td>
<td style="width: 6.39214%; background-color: #e3e1e1; height: 28px;"><span style="font-size: 10pt;">175-3300 nm</span></td>
<td style="width: 7.05377%; height: 28px;"><span style="font-size: 10pt;">175-1800 nm</span></td>
</tr>
<tr style="height: 61px;">
<td style="width: 3.9304%; height: 37px;"><span style="font-size: 10pt;">Résolution Spectrale</span></td>
<td style="width: 6.39214%; background-color: #e3e1e1; height: 37px;"><span style="font-size: 10pt;">UV-Vis : 0.01 - 5 nm
NIR : 0.04 - 20nm</span></td>
<td style="width: 7.05377%; height: 37px;"><span style="font-size: 10pt;">UV-Vis : 0.01 - 5 nm
NIR : 0.02 - 10nm</span></td>
</tr>
<tr style="height: 97px;">
<td style="width: 3.9304%; height: 97px;"><span style="font-size: 10pt;">Détecteur</span></td>
<td style="width: 6.39214%; background-color: #e3e1e1; height: 97px;"><span style="font-size: 10pt;">UV-Vis : Photomultiplicateur</span>
<span style="font-size: 10pt;">NIR : Photocellule PbS</span></td>
<td style="width: 7.05377%; height: 97px;"><span style="font-size: 10pt;">UV-Vis : Photomultiplicateur
</span>
<span style="font-size: 10pt;">NIR : Photodiode InGaAS
</span></td>
</tr>
<tr style="height: 112px;">
<td style="width: 3.9304%; height: 66px;"><span style="font-size: 10pt;">Source</span></td>
<td style="width: 6.39214%; background-color: #e3e1e1; height: 66px;"><span style="font-size: 10pt;">Vis : Tungstène-halogène</span>
<span style="font-size: 10pt;">UV : Deutérium</span></td>
<td style="width: 7.05377%; height: 66px;"><span style="font-size: 10pt;">Vis : Tungstène-halogène</span>
<span style="font-size: 10pt;">UV : Deutérium</span></td>
</tr>
</tbody>
</table>